Alarm Messages - 300s

The system inventory and maintenance service reports system changes with different degrees of severity. Use the reported alarms to monitor the overall health of the system.

For more information, see Overview.

In the following tables, the severity of the alarms is represented by one or more letters, as follows:

  • C: Critical

  • M: Major

  • m: Minor

  • W: Warning

A slash-separated list of letters is used when the alarm can be triggered with one of several severity levels.

An asterisk (*) indicates the management-affecting severity, if any. A management-affecting alarm is one that cannot be ignored at the indicated severity level or higher by using relaxed alarm rules during an orchestrated patch or upgrade operation.

Note

Differences exist between the terminology emitted by some alarms and that used in the CLI, GUI, and elsewhere in the documentations:

  • References to provider networks in alarms refer to data networks.

  • References to data networks in alarms refer to physical networks.

  • References to tenant networks in alarms refer to project networks.

Table 1. Alarm Messages

Alarm ID

Description

Severity

Proposed Repair Action

Entity Instance ID

300.001

‘Data’ Port failed.

M*

Check cabling and far-end port configuration and status on adjacent equipment.

host=<hostname>.port=<port-uuid>

300.002

‘Data’ Interface degraded or ‘Data’ Interface failed.

C/M*

Check cabling and far-end port configuration and status on adjacent equipment.

host=<hostname>.interface=<if-uuid>

300.003

Networking Agent not responding.

M*

If condition persists, attempt to clear issue by administratively locking and unlocking the Host.

host=<hostname>.agent=<agent-uuid>

300.004

No enabled compute host with connectivity to provider network.

M*

Enable compute hosts with required provider network connectivity.

host=<hostname>.providernet=<pnet-uuid>

300.005

Communication failure detected over provider network x% for ranges y% on host z%.

or

Communication failure detected over provider network x% on host z%.

M*

Check neighbor switch port VLAN assignments.

providernet=<pnet-uuid>.host=<hostname>

300.010

ML2 Driver Agent non-reachable

or

ML2 Driver Agent reachable but non-responsive

or

ML2 Driver Agent authentication failure

or

ML2 Driver Agent is unable to sync Neutron database

M*

Monitor and if condition persists, contact next level of support.

host=<hostname>.ml2driver=<driver>

300.012

Openflow Controller connection failed.

M*

Check cabling and far-end port configuration and status on adjacent equipment.

host=<hostname>.openflow-controller=<uri>

300.013

No active Openflow controller connections found for this network.

or

One or more Openflow controller connections in disconnected state for this network.

C, M*

Check cabling and far-end port configuration and status on adjacent equipment.

host=<hostname>.openflow-network=<name>

300.015

No active OVSDB connections found.

C*

Check cabling and far-end port configuration and status on adjacent equipment.

host=<hostname>

300.016

Dynamic routing agent x% lost connectivity to peer y%

M*

If condition persists, fix connectivity to peer

host=<hostname>,agent=<agent-uuid>,bgp-peer=<bgp-peer>