Install a Subcloud Using Redfish Platform Management Service¶
For subclouds with servers that support Redfish Virtual Media Service (version 1.2 or higher), you can use the Central Cloud’s CLI to install the ISO and bootstrap the subclouds from the Central Cloud.
About this task
After physically installing the hardware and network connectivity of a subcloud, the subcloud installation has these phases:
Executing the dcmanager subcloud add command in the Central Cloud:
Uses Redfish Virtual Media Service to remote install the ISO on controller-0 in the subcloud
Uses Ansible to bootstrap StarlingX on controller-0 in the subcloud
Note
After a successful remote installation of a subcloud in a Distributed Cloud
system, a subsequent remote reinstallation fails because of an existing ssh
key entry in the /root/.ssh/known_hosts
on the System Controller. In this
case, delete the host key entry, if present, from /root/.ssh/known_hosts
on the System Controller before doing reinstallations.
Note
Remove all removable USB storage devices from subcloud servers before starting a Redfish remote subcloud install.
Prerequisites
A new system CLI option
--active
is added to the load-import command to allow the import into the system controller/opt/dc-vault/loads
. The purpose of this is to allow Redfish install of subclouds referencing a single full copy of thebootimage.iso
at/opt/dc-vault/loads
. (Previously, the fullbootimage.iso
was duplicated for each subcloud add command).Note
This is required only once and does not have to be done for every subcloud install.
dcmanager recognizes bootimage names ending in
.iso
and.sig
.For example,
~(keystone_admin)]$ system --os-region-name SystemController load-import --active bootimage.iso bootimage.sig
The ISO imported via
load-import --active
must be at the same patch level as the system controller. This ensures that the subcloud boot image aligns with the patch level of the load to be installed on the subcloud.
Warning
If the patch level of load-imported ISO does not match the system controller patch level, the subcloud patch state may not align with the system controller patch state.
Run the load-import command on controller-0 to import the new release.
You can specify either the full file path or relative paths to the
*.iso
bootimage file and to the*.sig
bootimage signature file.$ source /etc/platform/openrc ~(keystone_admin)]$ system load-import [--local] /home/sysadmin/<bootimage>.iso <bootimage>.sig +--------------------+-----------+ | Property | Value | +--------------------+-----------+ | id | 2 | | state | importing | | software_version | nn.nn | | compatible_version | nn.nn | | required_patches | | +--------------------+-----------+
The load-import must be done on controller-0.
(Optional) If
--local
is specified, the ISO and sig files are uploaded directly from the active controller, where <local_iso_file_path> and <local_sig_file_path> are paths on the active controller to load ISO files and sig files respectively.Note
If
--local
is specified, the ISO and sig files are transferred directly from the active controller filesystem to the load directory, if it is not specified, the files are transferred via the API.Note
This will take a few minutes to complete.
In order to deploy subclouds from either controller, all local files that are referenced in the
subcloud-bootstrap-values.yaml
file must exist on both controllers (for example,/home/sysadmin/docker-registry-ca-cert.pem
).
Controlling the RVMC debug level and automatic serial console log capture¶
The optional parameter, rvmc_debug_level
, in the subcloud install_values
YAML file, controls the generation of debug logs during RVMC installation,
which are then stored in the ansible log files for each subcloud.
Valid rvmc_debug_levels
The available rvmc_debug_level
values control the log content as follows.
Note that the log levels increase in verbosity as they increase:
0: Debug logging is disabled (normal log content)
1: Logs operations of each remote install stage, such as RedFish session open/close, eject/insert image, power on/off host, and more. If the install_type matches a serial console, then the full serial console log output is also captured automatically.
2: Logs HTTP request type and URL with corresponding response status.
3: Logs HTTP request headers and payloads, along with Redfish action tracing logs.
4: Outputs JSON of all command responses.
Automatic Serial Console capture (for ``rvmc_debug_level`` > 1)
When the rvmc_debug_level
is enabled (rvmc_debug_level
> 0), the full serial
console output can be automatically captured, provided the serial console is
configured in the ‘install_type’ install value.
Note
Capturing graphical console output is not supported.
The install_type
in the subcloud install_values YAML file must correspond
to one of the serial console types:
0: Standard Controller, Serial Console
2: AIO, Serial Console
4: AIO Low-latency, Serial Console
The captured serial console log files are found in the same directory as the
subcloud ansible log files: /var/log/dcmanager/ansible
, and named as
<subcloud name>_serial_console.log
.
Procedure
At the subcloud location, physically install the servers and network connectivity required for the subcloud.
Note
Do not power off the servers. The host portion of the server can be powered off, but the BMC portion of the server must be powered and accessible from the system controller.
There is no need to wipe the disks.
Note
The servers require connectivity to a gateway router that provides IP routing between the subcloud management or admin subnet and the system controller management subnet, and between the subcloud OAM subnet and the system controller subnet.
Create the
subcloud-install-values.yaml
file and use the content to pass the file into the dcmanager subcloud add command, using the--install-values
command option.Note
If your controller is on a ZTSystems Triton server that requires a longer timeout value, you can now use the
rd.net.timeout.ipv6dad
dracut parameter to specify an increased timeout value for dracut to wait for the interface to have carrier, and complete IPv6 duplicate address detection DAD. For the ZTSystems server, this can take more than four minutes. It is recommended to set this value to 300 seconds, by specifying the following in thesubcloud-install-values.yaml
file:rd.net.timeout.ipv6dad: 300
Note
The
wait_for_timeout
value must be chosen based on your network performance (bandwidth, latency, and quality) and should be increased if the network does not meet the minimum or timeout requirements. The default value of 3600 seconds is based on a network bandwidth of 100 Mbps with a 50 ms delay.For example, --install-values /home/sysadmin/subcloud-install-values.yaml.
# Specify the StarlingX software version, for example 'nn.nn' for the StarlingX nn.nn release of software. software_version: <software_version> bootstrap_interface: <bootstrap_interface_name> # e.g. eno1 bootstrap_address: <bootstrap_interface_ip_address> # e.g.128.224.151.183 bootstrap_address_prefix: <bootstrap_netmask> # e.g. 23 # Board Management Controller bmc_address: <BMCs_IPv4_or_IPv6_address> # e.g. 128.224.64.180 bmc_username: <bmc_username> # e.g. root # If the subcloud's bootstrap IP interface and the system controller are not on the # same network then the customer must configure a default route or static route # so that the Central Cloud can login bootstrap the newly installed subcloud. # If nexthop_gateway is specified and the network_address is not specified then a # default route will be configured. Otherwise, if a network_address is specified then # a static route will be configured. nexthop_gateway: <default_route_address> for # e.g. 128.224.150.1 (required) network_address: <static_route_address> # e.g. 128.224.144.0 network_mask: <static_route_mask> # e.g. 255.255.254.0 # Installation type codes #0 - Standard Controller, Serial Console #1 - Standard Controller, Graphical Console #2 - AIO, Serial Console #3 - AIO, Graphical Console #4 - AIO Low-latency, Serial Console #5 - AIO Low-latency, Graphical Console install_type: 3 # Optional parameters defaults can be modified by uncommenting the option with a modified value. # This option can be set to extend the installing stage timeout value # wait_for_timeout: 3600 # Set this options for https no_check_certificate: True # If the bootstrap interface is a vlan interface then configure the vlan ID. # bootstrap_vlan: <vlan_id> # Override default filesystem device. # rootfs_device: "/dev/disk/by-path/pci-0000:00:1f.2-ata-1.0" # boot_device: "/dev/disk/by-path/pci-0000:00:1f.2-ata-1.0" # Set the value for persistent file system (/opt/platform-backup). # The value must be whole number (in MB) that is greater than or equal # to 30000. persistent_size: 30000 # Configure custom arguments applied at boot within the installed subcloud. # Multiple boot arguments can be provided by separating each argument by a # single comma. Spaces are not allowed. # Example: extra_boot_params: multi-drivers-switch=cvl-2.54 # extra_boot_params:
Note
By default, 30GB is allocated for
/opt/platform-backup
. If additional persistent disk space is required, the partition can be increased in the next subcloud reinstall using the following commands:To increase
/opt/platform-backup
to 40GB, add the persistent_size: 40000 parameter to thesubcloud-install-values.yaml
file.Use the dcmanager subcloud update command to save the configuration change for the next subcloud reinstall.
~(keystone_admin)]$ dcmanager subcloud update --install-values <subcloud-install-values.yaml> <subcloud-name>
For a new subcloud deployment, use the dcmanager subcloud add command with the
subcloud-install-values.yaml
file containing the desiredpersistent_size
value.At the system controller, create a
/home/sysadmin/subcloud-bootstrap-values.yaml
overrides file for the subcloud.For example:
system_mode: simplex name: "subcloud" description: "test" location: "loc" management_subnet: 192.168.101.0/24 management_start_address: 192.168.101.2 management_end_address: 192.168.101.50 management_gateway_address: 192.168.101.1 external_oam_subnet: 10.10.10.0/24 external_oam_gateway_address: 10.10.10.1 external_oam_floating_address: 10.10.10.12 systemcontroller_gateway_address: 192.168.204.101 docker_registries: k8s.gcr.io: url: registry.central:9001/k8s.gcr.io gcr.io: url: registry.central:9001/gcr.io ghcr.io: url: registry.central:9001/ghcr.io quay.io: url: registry.central:9001/quay.io docker.io: url: registry.central:9001/docker.io docker.elastic.co: url: registry.central:9001/docker.elastic.co registry.k8s.io: url: registry.central:9001/registry.k8s.io icr.io: url: registry.central:9001/icr.io defaults: username: sysinv password: <sysinv_password> type: docker
Where <sysinv_password> can be found by running the following command as ‘sysadmin’ on the Central Cloud:
$ keyring get sysinv services
In the above example, if the admin network is used for communication between the subcloud and system controller, then the
management_gateway_address
parameter should be replaced with admin subnet information.For example:
management_subnet: 192.168.101.0/24 management_start_address: 192.168.101.2 management_end_address: 192.168.101.50 admin_subnet: 192.168.102.0/24 admin_start_address: 192.168.102.2 admin_end_address: 192.168.102.50 admin_gateway_address: 192.168.102.1
This configuration will install container images from the local registry on your central cloud. The Central Cloud’s local registry’s HTTPS Certificate must have the Central Cloud’s OAM IP, registry.local and registry.central in the certificate’s SAN list. For example, a valid certificate contains a SAN list:
"DNS.1: registry.local DNS.2: registry.central IP.1: floating_management IP.2: floating_OAM"
If required, run the following command on the Central Cloud prior to bootstrapping the subcloud to install the new certificate for the Central Cloud with the updated SAN list:
~(keystone_admin)]$ system certificate-install -m docker_registry path_to_cert
If you prefer to install container images from the default external registries, make the following substitutions for the docker_registries sections of the file.
docker_registries: defaults: username: <your_default_registry_username> password: <your_default_registry_password>
Add the subcloud using dcmanager.
When calling the subcloud add command, specify the install values, bootstrap values and the subcloud’s sysadmin password.
~(keystone_admin)]$ dcmanager subcloud add \ --bootstrap-address <oam_ip_address_of_subclouds_controller-0> \ --bootstrap-values /home/sysadmin/subcloud1-bootstrap-values.yaml \ --sysadmin-password <sysadmin_password> \ --deploy-config /home/sysadmin/subcloud1-deploy-config.yaml \ --install-values /home/sysadmin/install-values.yaml \ --bmc-password <bmc_password>
If the
--sysadmin-password
is not specified, you are prompted to enter it once the full command is invoked. The password is masked when it is entered.Enter the sysadmin password for the subcloud:
The
--deploy-config
option must reference the deployment configuration file mentioned above. In the deployment configurations, static routes from the management or admin interface of a subcloud to the system controller’s management subnet must be explicitly listed. This ensures that the subcloud comes online after deployment. If the admin network is used for communication between the system controller and subcloud, the deployment configuration file must include both an admin network type and a management network type interface.(Optional) The
--bmc-password <password>
option is used for subcloud installation, and only required if the--install- values
option is specified.If the
--bmc-password <password>
option is omitted and the--install-values
option is specified the system administrator will be prompted to enter it, following the dcmanager subcloud add command. This option is ignored if the--install-values
option is not specified. The password is masked when it is entered.Enter the bmc password for the subcloud:
The dcmanager subcloud show or dcmanager subcloud list command can be used to view subcloud add progress.
At the Central Cloud / System Controller, monitor the progress of the subcloud install, bootstrapping, and deployment by using the deploy status field of the dcmanager subcloud list command.
For example:
~(keystone_admin)]$ dcmanager subcloud list +----+-----------+------------+--------------+---------------+---------+ | id | name | management | availability | deploy status | sync | +----+-----------+------------+--------------+---------------+---------+ | 1 | subcloud1 | unmanaged | online | complete | unknown | +----+-----------+------------+--------------+---------------+---------+
If deploy_status shows an installation, bootstrap or deployment failure state, you can use the dcmanager subcloud errors command in order to get more detailed information about failure.
For example:
sysadmin@controller-0 ~(keystone_admin)]$ dcmanager subcloud errors 1 FAILED bootstrapping playbook of (subcloud1). detail: fatal: [subcloud1]: FAILED! => changed=true failed_when_result: true msg: non-zero return code 500 Server Error: Internal Server Error ("manifest unknown: manifest unknown") Image download failed: admin-2.cumulus.mss.com: 30093/wind-river/cloud-platform-deployment-manager: WRCP_22.06 500 Server Error: Internal Server Error ("Get https://admin-2.cumulus .mss.com: 30093/v2/: dial tcp: lookup admin-2.cumulus.mss.com on 10.41.0.1:53: read udp 10.41.1.3:40251->10.41.0.1:53: i/o timeout") Image download failed: gcd.io/kubebuilder/kube-rdac-proxy:v0.11.0 500 Server Error: Internal Server Error ("Get https://gcd.io/v2/: dial tcp: lookup gcd.io on 10.41.0.1:53: read udp 10.41.1.3:52485->10.41.0.1:53: i/o timeout") raise Exception("Failed to download images %s" % failed_downloads) Exception: Failed to download images ["admin-2.cumulus.mss.com: 30093/wind-river/cloud-platform-deployment-manager: WRCP_22.06", "gcd.io kubebuilder/kube-rdac-proxy:v0.11.0"] FAILED TASK: TASK [common/push-docker-images Download images and push to local registry] Wednesday 12 October 2022 12:27:31 +0000 (0:00:00.042) 0:16:34.495
The deploy status field has the following values:
Pre-Install
This status indicates that the ISO for the subcloud is being updated by the Central Cloud with the boot menu parameters, and kickstart configuration as specified in the
install-values.yaml
file.Installing
This status indicates that the subcloud’s ISO is being installed from the Central Cloud to the subcloud using the Redfish Virtual Media service on the subcloud’s BMC.
Bootstrapping
This status indicates that the Ansible bootstrap of StarlingX software on the subcloud’s controller-0 is in progress.
Complete
This status indicates that subcloud deployment is complete.
The subcloud bootstrapping and deployment can take up to 30 minutes.
Caution
If there is an installation failure, or a failure during bootstrapping, you must delete the subcloud before re-adding it, using the dcmanager subcloud add command. For more information on deleting, managing or unmanaging a subcloud, see Managing Subclouds Using the CLI.
If there is a deployment failure, do not delete the subcloud, use the subcloud reconfig command, to reconfigure the subcloud. For more information, see Managing Subclouds Using the CLI.
You can also monitor detailed logging of the subcloud installation, bootstrapping and deployment by monitoring the following log files on the active controller in the Central Cloud.
/var/log/dcmanager/ansible/<subcloud_name>_playbook_output.log
For example:
controller-0:/home/sysadmin# tail /var/log/dcmanager/ansible/subcloud_playbook_output.log k8s.gcr.io: {password: secret, url: null} quay.io: {password: secret, url: null} ) TASK [bootstrap/bringup-essential-services : Mark the bootstrap as completed] *** changed: [subcloud] PLAY RECAP ********************************************************************* subcloud : ok=230 changed=137 unreachable=0 failed=0
Note
The subcloud_playbook_output.log can rotate, the previous log file will be subcloud_playbook_output.log.1.
Postrequisites
Provision the newly installed and bootstrapped subcloud. For detailed StarlingX deployment procedures for the desired deployment configuration of the subcloud, see the post-bootstrap steps of StarlingX Installation.
Check and update docker registry credentials on the subcloud:
REGISTRY="docker-registry" SECRET_UUID='system service-parameter-list | fgrep $REGISTRY | fgrep auth-secret | awk '{print $10}'' SECRET_REF='openstack secret list | fgrep $ {SECRET_UUID} | awk '{print $2}'' openstack secret get ${SECRET_REF} --payload -f value
The secret payload should be,
username: sysinv password:<password>
. If the secret payload is, “username: admin password:<password>”, see, Updating Docker Registry Credentials on a Subcloud for more information.For more information on bootstrapping and deploying, see the procedures listed under Installation.
Add static route for nodes in subcloud to access openldap service.
In a Distributed Cloud system, openldap service is running on Central Cloud. In order for the nodes in the subclouds to access openldap service, such as ssh to the nodes as openldap users, a static route to the System Controller is required to be added in these nodes. This applies to controller nodes, worker nodes and storage nodes (nodes that have sssd running).
The static route can be added on each of the nodes in the subcloud using system CLI.
The following examples show how to add the static route in controller node and worker node:
[sysadmin@controller-0 ~(keystone_admin)]$ system host-route-add controller-0 mgmt0 <Central Cloud mgmt subnet> 64 <Gateway IP address> [sysadmin@controller-0 ~(keystone_admin)]$ system host-route-add compute-0 mgmt0 <Central Cloud mgmt subnet> 64 <Gateway IP address>
The static route can also be added using Deployment Manager by adding the route in its configuration file.
The following examples show adding the route configuration in controller and worker host profiles of the deployment manager’s configuration file:
Controller node: --- apiVersion: starlingx.windriver.com/v1 kind: HostProfile metadata: labels: controller-tools.k8s.io: "1.0" name: controller-0-profile namespace: deployment spec: administrativeState: unlocked bootDevice: /dev/disk/by-path/pci-0000:c3:00.0-nvme-1 console: ttyS0,115200n8 installOutput: text ...... routes: - gateway: <Gateway IP address> activeinterface: mgmt0 metric: 1 prefix: 64 subnet: <Central Cloud mgmt subnet> Worker node: --- apiVersion: starlingx.windriver.com/v1 kind: HostProfile metadata: labels: controller-tools.k8s.io: "1.0" name: compute-0-profile namespace: deployment spec: administrativeState: unlocked boardManagement: credentials: password: secret: bmc-secret type: dynamic bootDevice: /dev/disk/by-path/pci-0000:00:1f.2-ata-1.0 clockSynchronization: ntp console: ttyS0,115200n8 installOutput: text ...... routes: - gateway: <Gateway IP address> interface: mgmt0 metric: 1 prefix: 64 subnet: <Central Cloud mgmt subnet>