300 Series Alarm Messages

Alarm Severities

One or more of the following severity levels is associated with each alarm.

Critical

Indicates that a platform service affecting condition has occurred and immediate corrective action is required. (A mandatory platform service has become totally out of service and its capability must be restored.)

Major

Indicates that a platform service affecting condition has developed and urgent corrective action is required. (A mandatory platform service has developed a severe degradation and its full capability must be restored.)

- or -

An optional platform service has become totally out of service and its capability should be restored.

Minor

Indicates that a platform non-service affecting fault condition has developed and corrective action should be taken in order to prevent a more serious fault. (The fault condition is not currently impacting / degrading the capability of the platform service.)

Warning

Indicates the detection of a potential or impending service affecting fault. Action should be taken to further diagnose and correct the problem in order to prevent it from becoming a more serious service affecting fault.


Alarm ID: 300.001

‘Data’ Port failed.

Entity Instance

host=<hostname>.port=<port-uuid>

Degrade Affecting Severity:

none

Severity:

major

Proposed Repair Action

Check cabling and far-end port configuration and status on adjacent equipment.

Management Affecting Severity

warning